On May 3, 2010, at 11:11 AM, Matthew Fredrickson wrote: > > Bryan Scott wrote: >> They do match.... I have them separated by "pointcode"... >> >> Switched back to 1.6.2.6 (1.6.1.18 was giving me grief on some SIP RTP stuff). >> >> >> On Mon, May 3, 2010 at 6:36 AM, Paul Timmins <paul at timmins.net> wrote: >>> Why do defaultdpc and adjpointcode not match? Do you have an stp between? > > Can you post a debug of the messages using "ss7 debug linkset x" where x > is the linkset number? > > UGHHH!H!H!!! Ok. Well, in troubleshooting everything *else*, I neglected to take a close look at the point codes. Yeah.... I put a 2 where I should have put a 7. Changed that, reloaded chan_dahdi, and voila: ==================== Loaded chan_dahdi.so => (DAHDI Telephony Driver w/PRI & SS7) == Primary D-Channel on span 1 up MTP2 link up (SLC 0) --- SS7 Up --- Resetting CICs 25 to 47 Got reset acknowledgement from CIC 25 to 47. ==================== And all alarms have cleared on the switch and tests are passing: ==================== << Query Circuit ... << PC: 1 - 1 - 10, CIC: 00025 >> >> T7000 ISUP Circuit Query >> >> Circuit Near End State Far End State >> *************************************************** >> 0025 idle idle << Query Circuit Range ... << PC: 1 - 1 - 10, CIC: 00025, 00026, 00027, 00028, 00029, 00030, 00031, 00032, 00033, 00034, 00035, 00036, 00037, 00038, 00039, 00040, 00041, 00042, 00043, 00044, 00045, 00046, 00047 >> >> T7000 ISUP Circuit Query >> >> Circuit Near End State Far End State >> *************************************************** >> 0025 idle idle >> 0026 idle idle >> 0027 transient idle >> 0028 transient idle >> 0029 transient idle >> 0030 transient idle >> 0031 transient idle >> 0032 transient idle >> 0033 transient idle >> 0034 transient idle >> 0035 transient idle >> 0036 transient idle >> 0037 transient idle >> 0038 transient idle >> 0039 transient idle >> 0040 transient idle >> 0041 transient idle >> 0042 transient idle >> 0043 transient idle >> 0044 transient idle >> 0045 transient idle >> 0046 transient idle >> 0047 transient idle << Circuit Continuity Check Request ... << PC: 1 - 1 - 10, CIC: 00047 >> >> --------------------------------------------------- >> T7000 ISUP COT PASSED >> PC:CIC (1-1-10:47), CID: (22) >> --------------------------------------------------- << Test Circuit ... << PC: 1 - 1 - 10, CIC: 00047 >> OCX Circuit Validation Test >> ************************************************ >> circuit 47 success. >> Circuit Group Carrier -> unknown >> Double Seizing Control -> none >> Alarm Carrier -> unknown >> Cot Check Req -> unknown << Reset Circuit ... << PC: 1 - 1 - 10, CIC: 00047