Hi, I am using two T1 for SS7 on the same box. Both T1s are using the same point codes. I have each T1 setup as its own linkset (Linkset 1 and linkset 2). The second linkset is not coming up. Is there any thing wrong with my config or setup? Can I have both T1s usins the same point code. I did it this way so that if 1 T1 goes down the second linkset and T1 stays up. [trunkgroups] [channels] context=in_dahdi switchtype=national usecallerid=yes callwaiting=yes usecallingpres=yes callwaitingcallerid=yes threewaycalling=yes transfer=yes canpark=yes cancallforward=yes callreturn=yes echocancel=yes echocancelwhenbridged=yes signalling = ss7 ss7type = ansi group=1 callgroup=1 pickupgroup=1 ss7_called_nai=dynamic ss7_calling_nai=dynamic ss7_internationalprefix = 00 ss7_nationalprefix = 0 ; All settings apply to linkset 1 linkset = 1 context=in_dahdi pointcode = 157 adjpointcode = 163 defaultdpc = 163 networkindicator=national cicbeginswith = 102 channel = 2-24 sigchan = 1 group = 2 linkset = 2 context=in_dahdi pointcode = 157 adjpointcode = 163 defaultdpc = 163 networkindicator=national cicbeginswith = 126 channel = 26-48 sigchan = 25 Thanks, Dave George Teletone Inc. 561 674 3838