[PATCH v2] drm/amd/pm: workaround for compute workload type on some skus

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On smu 13.0.0, the compute workload type cannot be set on all the skus
due to some other problems. This workaround is to make sure compute workload type
can also run on some specific skus.

v2: keep the variable consistent

Signed-off-by: Kenneth Feng <kenneth.feng@xxxxxxx>
---
 .../drm/amd/pm/swsmu/smu13/smu_v13_0_0_ppt.c  | 33 +++++++++++++++++--
 1 file changed, 31 insertions(+), 2 deletions(-)

diff --git a/drivers/gpu/drm/amd/pm/swsmu/smu13/smu_v13_0_0_ppt.c b/drivers/gpu/drm/amd/pm/swsmu/smu13/smu_v13_0_0_ppt.c
index e2265f50bacc..5e9e507a710e 100644
--- a/drivers/gpu/drm/amd/pm/swsmu/smu13/smu_v13_0_0_ppt.c
+++ b/drivers/gpu/drm/amd/pm/swsmu/smu13/smu_v13_0_0_ppt.c
@@ -2179,10 +2179,39 @@ static int smu_v13_0_0_set_power_profile_mode(struct smu_context *smu,
 		}
 	}
 
-	/* conv PP_SMC_POWER_PROFILE* to WORKLOAD_PPLIB_*_BIT */
-	workload_type = smu_cmn_to_asic_specific_index(smu,
+	if (smu->power_profile_mode == PP_SMC_POWER_PROFILE_COMPUTE &&
+		(((smu->adev->pdev->device == 0x744C) && (smu->adev->pdev->revision == 0xC8)) ||
+		((smu->adev->pdev->device == 0x744C) && (smu->adev->pdev->revision == 0xCC)))) {
+		ret = smu_cmn_update_table(smu,
+					   SMU_TABLE_ACTIVITY_MONITOR_COEFF,
+					   WORKLOAD_PPLIB_COMPUTE_BIT,
+					   (void *)(&activity_monitor_external),
+					   false);
+		if (ret) {
+			dev_err(smu->adev->dev, "[%s] Failed to get activity monitor!", __func__);
+			return ret;
+		}
+
+		ret = smu_cmn_update_table(smu,
+					   SMU_TABLE_ACTIVITY_MONITOR_COEFF,
+					   WORKLOAD_PPLIB_CUSTOM_BIT,
+					   (void *)(&activity_monitor_external),
+					   true);
+		if (ret) {
+			dev_err(smu->adev->dev, "[%s] Failed to set activity monitor!", __func__);
+			return ret;
+		}
+
+		workload_type = smu_cmn_to_asic_specific_index(smu,
+						       CMN2ASIC_MAPPING_WORKLOAD,
+						       PP_SMC_POWER_PROFILE_CUSTOM);
+	} else {
+		/* conv PP_SMC_POWER_PROFILE* to WORKLOAD_PPLIB_*_BIT */
+		workload_type = smu_cmn_to_asic_specific_index(smu,
 						       CMN2ASIC_MAPPING_WORKLOAD,
 						       smu->power_profile_mode);
+	}
+
 	if (workload_type < 0)
 		return -EINVAL;
 
-- 
2.34.1