On 06/15/2016 11:25 AM, Mark Brown wrote: > On Tue, Jun 14, 2016 at 04:52:15PM +0200, Sylwester Nawrocki wrote: >> > On 06/13/2016 05:14 PM, Mark Brown wrote: >>> > > Removed the regulator handling code? Why? >> > Because it was effectively a dead code (disabled by a DT flag property) >> > and didn't make any sense on our test board. It was setting regulator's >> > load and voltage on a shared fixed voltage regulator. Even if calls like >> > regulator_set_optimum_mode() were added that wouldn't make any difference, >> > since the corresponding PMIC driver ops were not implemented. >> > I started more or less with something like this [1]. > > The mode and voltage setting code there are just obviously broken but > having the get and enable is useful, even if it doesn't do anything on > your board it's nice to have them there already to avoid any transition > issues adding them later and help get more complete and accurate DTs in > from the get go. OK, I've added regulator supply related code and properties to the DT binding. _______________________________________________ Alsa-devel mailing list Alsa-devel@xxxxxxxxxxxxxxxx http://mailman.alsa-project.org/mailman/listinfo/alsa-devel