On Mon, 2010-11-08 at 10:57 +0200, Jarkko Nikula wrote: > There are no known problems with current power-up sequence which first sets > the /shutdown pin high and then enables the supply. However, swap the order > so that the device is kept in shutdown/reset mode during the supply voltage > transition since slowly rising voltages can usually cause problems if the > device is not kept in reset. > > Signed-off-by: Jarkko Nikula <jhnikula@xxxxxxxxx> > Cc: Peter Ujfalusi <peter.ujfalusi@xxxxxxxxx> > --- > sound/soc/codecs/tpa6130a2.c | 7 +++---- > 1 files changed, 3 insertions(+), 4 deletions(-) > Applied. Thanks Liam -- Freelance Developer, SlimLogic Ltd ASoC and Voltage Regulator Maintainer. http://www.slimlogic.co.uk _______________________________________________ Alsa-devel mailing list Alsa-devel@xxxxxxxxxxxxxxxx http://mailman.alsa-project.org/mailman/listinfo/alsa-devel