Re: [PATCH] ASoC: tpa6130a2: Revisit power-up sequence

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Mon, Nov 08, 2010 at 10:57:57AM +0200, Jarkko Nikula wrote:
> There are no known problems with current power-up sequence which first sets
> the /shutdown pin high and then enables the supply. However, swap the order
> so that the device is kept in shutdown/reset mode during the supply voltage
> transition since slowly rising voltages can usually cause problems if the
> device is not kept in reset.
> 
> Signed-off-by: Jarkko Nikula <jhnikula@xxxxxxxxx>
> Cc: Peter Ujfalusi <peter.ujfalusi@xxxxxxxxx>

Acked-by: Mark Brown <broonie@xxxxxxxxxxxxxxxxxxxxxxxxxxx>