On 06-05-22, 09:47, Srinivas Kandagatla wrote: > Currently timeout for autoenumeration during probe and bus reset is set to > 2 secs which is really a big value. This can have an adverse effect on > boot time if the slave device is not ready/reset. > This was the case with wcd938x which was not reset yet but we spent 2 > secs waiting in the soundwire controller probe. Reduce this time to > 1/10 of Hz which should be good enough time to finish autoenumeration > if any slaves are available on the bus. Applied, thanks -- ~Vinod