Currently timeout for autoenumeration during probe and bus reset is set to 2 secs which is really a big value. This can have an adverse effect on boot time if the slave device is not ready/reset. This was the case with wcd938x which was not reset yet but we spent 2 secs waiting in the soundwire controller probe. Reduce this time to 1/10 of Hz which should be good enough time to finish autoenumeration if any slaves are available on the bus. Reported-by: Srinivasa Rao Mandadapu <quic_srivasam@xxxxxxxxxxx> Signed-off-by: Srinivas Kandagatla <srinivas.kandagatla@xxxxxxxxxx> --- Changes since v1: replaced HZ/10 with 100 as suggested by Pierre drivers/soundwire/qcom.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/drivers/soundwire/qcom.c b/drivers/soundwire/qcom.c index 7367aa88b8ac..d6111f69d320 100644 --- a/drivers/soundwire/qcom.c +++ b/drivers/soundwire/qcom.c @@ -105,7 +105,7 @@ #define SWRM_SPECIAL_CMD_ID 0xF #define MAX_FREQ_NUM 1 -#define TIMEOUT_MS (2 * HZ) +#define TIMEOUT_MS 100 #define QCOM_SWRM_MAX_RD_LEN 0x1 #define QCOM_SDW_MAX_PORTS 14 #define DEFAULT_CLK_FREQ 9600000 -- 2.21.0