This controller can be connected only to a port on a "pcie-switch-upstream-port". It provides a single hotpluggable port that will accept any PCI or PCIe device. --- docs/formatdomain.html.in | 31 +++++++++++++------ docs/schemas/domaincommon.rng | 1 + src/conf/domain_addr.c | 6 ++++ src/conf/domain_conf.c | 3 +- src/conf/domain_conf.h | 1 + .../qemuxml2argv-pcie-switch-downstream-port.xml | 36 ++++++++++++++++++++++ tests/qemuxml2xmltest.c | 1 + 7 files changed, 68 insertions(+), 11 deletions(-) create mode 100644 tests/qemuxml2argvdata/qemuxml2argv-pcie-switch-downstream-port.xml diff --git a/docs/formatdomain.html.in b/docs/formatdomain.html.in index 646c9ee..7e16dc4 100644 --- a/docs/formatdomain.html.in +++ b/docs/formatdomain.html.in @@ -2998,11 +2998,12 @@ PCI controllers have an optional <code>model</code> attribute with possible values <code>pci-root</code>, <code>pcie-root</code>, <code>pcie-root-port</code>, <code>pci-bridge</code>, - <code>dmi-to-pci-bridge</code>, or <code>pcie-switch-upstream-port</code>. + <code>dmi-to-pci-bridge</code>, <code>pcie-switch-upstream-port</code>, or + <code>pcie-switch-downstream-port</code>. (pci-root and pci-bridge <span class="since">since 1.0.5</span>, pcie-root and dmi-to-pci-bridge <span class="since">since - 1.1.2</span>, pcie-root-port and - pcie-switch-upstream-port <span class="since">since 1.2.17</span>) + 1.1.2</span>, pcie-root-port, pcie-switch-upstream-port, and + pcie-switch-downstream-port <span class="since">since 1.2.30</span>) The root controllers (<code>pci-root</code> and <code>pcie-root</code>) have an optional <code>pcihole64</code> element specifying how big (in kilobytes, or in the unit specified by <code>pcihole64</code>'s @@ -3058,14 +3059,24 @@ </p> <p> Domains with an implicit pcie-root can also add controllers - with <code>model='pcie-root-port'</code>. This is a simple type of - bridge device that can connect only to one of the 31 slots on - the pcie-root bus on its upstream side, and makes a single - (PCIe, hotpluggable) port (at slot='0') available on the - downstream side. This controller can be used to provide a single - slot to later hotplug a PCIe device (but is not itself + with <code>model='pcie-root-port'</code>, + <code>model='pcie-switch-upstream-port'</code>, + and <code>model='pcie-switch-downstream-port'</code>. pcie-root-port + is a simple type of bridge device that can connect only to one + of the 31 slots on the pcie-root bus on its upstream side, and + makes a single (PCIe, hotpluggable) port (at slot='0') available + on the downstream side. This controller can be used to provide a + single slot to later hotplug a PCIe device (but is not itself hotpluggable - it must be in the configuration when the domain - is started). (<span class="since">since 1.2.17</span>) + is started). pcie-switch-upstream-port is a more flexible (but + also more complex) device that can plug into any PCIe port on + the upstream side, and provides 31 ports on the downstream side + that accept only pcie-switch-downstream-port devices; each + pcie-switch-downstream-port device can only plug into a + pcie-switch-upstream-port on its upstream side, and on its + downstream side provides a single hotpluggable pcie port that + can accept any standard pci or pcie device. + (<span class="since">since 1.2.30</span>) </p> <pre> ... diff --git a/docs/schemas/domaincommon.rng b/docs/schemas/domaincommon.rng index 3f74cfc..490c0e7 100644 --- a/docs/schemas/domaincommon.rng +++ b/docs/schemas/domaincommon.rng @@ -1753,6 +1753,7 @@ <value>dmi-to-pci-bridge</value> <value>pcie-root-port</value> <value>pcie-switch-upstream-port</value> + <value>pcie-switch-downstream-port</value> </choice> </attribute> </group> diff --git a/src/conf/domain_addr.c b/src/conf/domain_addr.c index 59da745..b97a62c 100644 --- a/src/conf/domain_addr.c +++ b/src/conf/domain_addr.c @@ -211,6 +211,12 @@ virDomainPCIAddressBusSetModel(virDomainPCIAddressBusPtr bus, bus->minSlot = 1; bus->maxSlot = 31; break; + case VIR_DOMAIN_CONTROLLER_MODEL_PCIE_SWITCH_DOWNSTREAM_PORT: + /* provides one slot which is pcie and hotpluggable */ + bus->flags = VIR_PCI_CONNECT_TYPE_PCIE | VIR_PCI_CONNECT_HOTPLUGGABLE; + bus->minSlot = 0; + bus->maxSlot = 0; + break; default: virReportError(VIR_ERR_INTERNAL_ERROR, _("Invalid PCI controller model %d"), model); diff --git a/src/conf/domain_conf.c b/src/conf/domain_conf.c index c0b8c92..8987e81 100644 --- a/src/conf/domain_conf.c +++ b/src/conf/domain_conf.c @@ -325,7 +325,8 @@ VIR_ENUM_IMPL(virDomainControllerModelPCI, VIR_DOMAIN_CONTROLLER_MODEL_PCI_LAST, "pci-bridge", "dmi-to-pci-bridge", "pcie-root-port", - "pcie-switch-upstream-port") + "pcie-switch-upstream-port", + "pcie-switch-downstream-port") VIR_ENUM_IMPL(virDomainControllerModelSCSI, VIR_DOMAIN_CONTROLLER_MODEL_SCSI_LAST, "auto", diff --git a/src/conf/domain_conf.h b/src/conf/domain_conf.h index b7ce0ce..1351eef 100644 --- a/src/conf/domain_conf.h +++ b/src/conf/domain_conf.h @@ -754,6 +754,7 @@ typedef enum { VIR_DOMAIN_CONTROLLER_MODEL_DMI_TO_PCI_BRIDGE, VIR_DOMAIN_CONTROLLER_MODEL_PCIE_ROOT_PORT, VIR_DOMAIN_CONTROLLER_MODEL_PCIE_SWITCH_UPSTREAM_PORT, + VIR_DOMAIN_CONTROLLER_MODEL_PCIE_SWITCH_DOWNSTREAM_PORT, VIR_DOMAIN_CONTROLLER_MODEL_PCI_LAST } virDomainControllerModelPCI; diff --git a/tests/qemuxml2argvdata/qemuxml2argv-pcie-switch-downstream-port.xml b/tests/qemuxml2argvdata/qemuxml2argv-pcie-switch-downstream-port.xml new file mode 100644 index 0000000..7d30bd1 --- /dev/null +++ b/tests/qemuxml2argvdata/qemuxml2argv-pcie-switch-downstream-port.xml @@ -0,0 +1,36 @@ +<domain type='qemu'> + <name>q35-test</name> + <uuid>11dbdcdd-4c3b-482b-8903-9bdb8c0a2774</uuid> + <memory unit='KiB'>2097152</memory> + <currentMemory unit='KiB'>2097152</currentMemory> + <vcpu placement='static' cpuset='0-1'>2</vcpu> + <os> + <type arch='x86_64' machine='q35'>hvm</type> + <boot dev='hd'/> + </os> + <clock offset='utc'/> + <on_poweroff>destroy</on_poweroff> + <on_reboot>restart</on_reboot> + <on_crash>destroy</on_crash> + <devices> + <emulator>/usr/libexec/qemu-kvm</emulator> + <disk type='block' device='disk'> + <source dev='/dev/HostVG/QEMUGuest1'/> + <target dev='sda' bus='sata'/> + <address type='drive' controller='0' bus='0' target='0' unit='0'/> + </disk> + <controller type='pci' index='0' model='pcie-root'/> + <controller type='pci' index='1' model='dmi-to-pci-bridge'/> + <controller type='pci' index='2' model='pci-bridge'/> + <controller type='pci' index='3' model='pcie-switch-upstream-port'/> + <controller type='pci' index='4' model='pcie-switch-downstream-port'/> + <controller type='pci' index='5' model='pcie-switch-downstream-port'/> + <controller type='pci' index='6' model='pcie-switch-downstream-port'/> + <controller type='pci' index='7' model='pcie-switch-downstream-port'/> + <controller type='sata' index='0'/> + <video> + <model type='qxl' ram='65536' vram='32768' vgamem='8192' heads='1'/> + </video> + <memballoon model='none'/> + </devices> +</domain> diff --git a/tests/qemuxml2xmltest.c b/tests/qemuxml2xmltest.c index e5fcc5d..d121fa0 100644 --- a/tests/qemuxml2xmltest.c +++ b/tests/qemuxml2xmltest.c @@ -568,6 +568,7 @@ mymain(void) DO_TEST_DIFFERENT("q35"); DO_TEST("pcie-root-port"); DO_TEST("pcie-switch-upstream-port"); + DO_TEST("pcie-switch-downstream-port"); DO_TEST("hostdev-scsi-lsi"); DO_TEST("hostdev-scsi-virtio-scsi"); -- 2.1.0 -- libvir-list mailing list libvir-list@xxxxxxxxxx https://www.redhat.com/mailman/listinfo/libvir-list