Now that MD BIOS RAID arrays have their own type, there is no longer a need for the biosraid property. --- iw/partition_gui.py | 2 +- storage/devices.py | 7 ------- 2 files changed, 1 insertions(+), 8 deletions(-) diff --git a/iw/partition_gui.py b/iw/partition_gui.py index 981b659..2e9be5f 100644 --- a/iw/partition_gui.py +++ b/iw/partition_gui.py @@ -1000,7 +1000,7 @@ class PartitionWindow(InstallWindow): self.tree[iter]['IsLeaf'] = True # handle RAID next - mdarrays = [a for a in self.storage.mdarrays if not a.biosraid] + mdarrays = self.storage.mdarrays if mdarrays: raidparent = self.tree.append(None) self.tree[raidparent]['Device'] = _("RAID Devices") diff --git a/storage/devices.py b/storage/devices.py index f2ff639..ef920de 100644 --- a/storage/devices.py +++ b/storage/devices.py @@ -2828,13 +2828,6 @@ class MDRaidArrayDevice(StorageDevice): return "RAID%d Array" % self.level @property - def biosraid(self): - """ Is this a BIOS RAID related set? """ - return self.type == "mdcontainer" or \ - (len(self.devices) != 0 and \ - self.devices[0].type == "mdcontainer") - - @property def partitionable(self): return len(self.devices) != 0 and \ self.devices[0].type == "mdcontainer" -- 1.6.5.2 _______________________________________________ Anaconda-devel-list mailing list Anaconda-devel-list@xxxxxxxxxx https://www.redhat.com/mailman/listinfo/anaconda-devel-list