Re: [PATCH 2/4] Remove loader from the reboot/shutdown/halt picture.

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



comment inline

On 11/23/2009 09:40 PM, Chris Lumens wrote:
> Right now, rebooting/halting after installation is handled in at least
> three places:  anaconda knows how to do some things, loader knows how to do
> some others, and init knows how to do everything.  loader really just does a
> bunch of signal handling and process exit status checking to figure out how
> to signal init which is completely unnecessary.  Instead, loader should just
> exec anaconda and then get out of the picture.
> ---
>  loader/loader.c |   68 +++---------------------------------------------------
>  1 files changed, 4 insertions(+), 64 deletions(-)
> 
> diff --git a/loader/loader.c b/loader/loader.c
> index cd3e178..5502553 100644
> --- a/loader/loader.c
> +++ b/loader/loader.c
> @@ -123,9 +123,6 @@ uint64_t flags = LOADER_FLAGS_SELINUX;
>  int num_link_checks = 5;
>  int post_link_sleep = 0;
> 
> -static pid_t init_pid = 1;
> -static int init_sig = SIGUSR1; /* default to shutdown=halt */
> -
>  static struct installMethod installMethods[] = {
>      { N_("Local CD/DVD"), 0, DEVICE_CDROM, mountCdromImage },
>      { N_("Hard drive"), 0, DEVICE_DISK, mountHardDrive },
> @@ -1726,11 +1723,6 @@ static void setupBacktrace(void)
>      backtrace(&array, 1);
>  }
> 
> -void loaderUsrXHandler(int signum) {
> -    logMessage(INFO, "Remembering signal %d\n", signum);
> -    init_sig = signum;
> -}
> -
>  static int anaconda_trace_init(void) {
>  #ifdef USE_MTRACE
>      setenv("MALLOC_TRACE","/malloc",1);
> @@ -1802,26 +1794,6 @@ int main(int argc, char ** argv) {
>          { NULL },
>      };
> 
> -    /* get init PID if we have it */
> -    if ((f = fopen("/var/run/init.pid", "r")) != NULL) {
> -        char linebuf[256];
> -        memset(linebuf, '\0', sizeof(linebuf));
> -
> -        while (fgets(linebuf, sizeof(linebuf) - 1, f) != NULL) {
> -            errno = 0;
> -            init_pid = strtol((const char *) &linebuf, NULL, 10);
> -            if (errno == EINVAL || errno == ERANGE) {
> -                logMessage(ERROR, "%s (%d): %m", __func__, __LINE__);
> -                init_pid = 1;
> -            }
> -        }
> -
> -        fclose(f);
> -    }
> -
> -    signal(SIGUSR1, loaderUsrXHandler);
> -    signal(SIGUSR2, loaderUsrXHandler);
> -
>      /* Make sure sort order is right. */
>      setenv ("LC_COLLATE", "C", 1);	
> 
> @@ -2253,7 +2225,6 @@ int main(int argc, char ** argv) {
>      closeLog();
>      
>      if (!FL_TESTING(flags)) {
> -        int pid, status, rc;
>          char *fmt;
> 
>          if (FL_RESCUE(flags)) {
> @@ -2263,44 +2234,13 @@ int main(int argc, char ** argv) {
>          }
>          printf(fmt, VERSION, getProductName());
> 
> -        if (!(pid = fork())) {
> -            if (execv(anacondaArgs[0], anacondaArgs) == -1) {
> -               fprintf(stderr,"exec of anaconda failed: %m\n");
> -               doExit(1);
> -            }
> -        }
> -
> -        waitpid(pid, &status, 0);
> -
> -        if (!WIFEXITED(status) || (WIFEXITED(status) && WEXITSTATUS(status))) {
> -            rc = 1;
> -        } else {
> -            rc = 0;
> -        }
> -
> -        if ((rc == 0) && (FL_POWEROFF(flags) || FL_HALT(flags))) {
> -            if (!(pid = fork())) {
> -                char * cmd = (FL_POWEROFF(flags) ? strdup("/sbin/poweroff") :
> -                              strdup("/sbin/halt"));
> -                if (execl(cmd, cmd, NULL) == -1) {
> -                    fprintf(stderr, "exec of poweroff failed: %m\n");
> -                    doExit(1);
> -                }
> -            }
> -            waitpid(pid, &status, 0);
> +        if (execv(anacondaArgs[0], anacondaArgs) == -1) {
> +           fprintf(stderr,"exec of anaconda failed: %m\n");
> +           doExit(1);
>          }
> -
> -        stop_fw_loader(&loaderData);
> -#if defined(__s390__) || defined(__s390x__)
> -        /* at the latest possibility signal init=linuxrc.s390 to reboot/halt */
> -        logMessage(INFO, "Sending signal %d to process %d\n",
> -                   init_sig, init_pid);
> -        kill(init_pid, init_sig);
> -#endif

I guess util.py:reIPLtrigger() would now have to call init
(=linuxrc.s390) as reboot or halt instead of killing its parent loader
with SIGUSR2 or SIGUSR1.

> -        doExit(rc);
>      }
> 
> -    doExit(1);
> +    return 0;
>  }
> 
>  /* vim:set sw=4 sts=4 et: */

Steffen

Linux on System z Development

IBM Deutschland Research & Development GmbH
Vorsitzender des Aufsichtsrats: Martin Jetter
Geschäftsführung: Dirk Wittkopp
Sitz der Gesellschaft: Böblingen
Registergericht: Amtsgericht Stuttgart, HRB 243294


_______________________________________________
Anaconda-devel-list mailing list
Anaconda-devel-list@xxxxxxxxxx
https://www.redhat.com/mailman/listinfo/anaconda-devel-list

[Index of Archives]     [Kickstart]     [Fedora Users]     [Fedora Legacy List]     [Fedora Maintainers]     [Fedora Desktop]     [Fedora SELinux]     [Big List of Linux Books]     [Yosemite News]     [Yosemite Photos]     [KDE Users]     [Fedora Tools]
  Powered by Linux