Le Fri, 3 Jun 2016 22:28:54 -0400 Andrew Ryder <tireman@xxxxxxx> écrivait: > Sorry to dig up old stuff here but after replacing hardware and > pulling my hair out to no end, I traced the source of the problem out. > > On every drive in the array, the points on the PCB which the contacts > for the drives motors and head/actuators make contact with were > oxidized enough to cause the issue. I ended up pulling the PCB off > each drive and cleaning them as well as cleaning out all other cable > and drive connectors from the HBA outward and everything is happy > again. > > http://s33.postimg.org/uhjmvw4dr/Not_Cleaned.jpg > http://s33.postimg.org/xo94ieii7/Partial_Cleaned_1.jpg > http://s33.postimg.org/hoqgyumgf/Partial_Cleaned_2.jpg > http://s33.postimg.org/68k20t8a7/Partial_Cleaned_3.jpg > Good job, that was quite unexpected :) Are you next to the seashore? -- ------------------------------------------------------------------------ Emmanuel Florac | Direction technique | Intellique | <eflorac@xxxxxxxxxxxxxx> | +33 1 78 94 84 02 ------------------------------------------------------------------------ _______________________________________________ xfs mailing list xfs@xxxxxxxxxxx http://oss.sgi.com/mailman/listinfo/xfs