[PATCH] wireless-regdb: Update regulatory rules for Croatia (HR)

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Croatian Regulatory Authority for Network Industries (HAKOM) has
updated the general licenses OD-85 and OD-86 with the new OD-85a
and OD-86a versions.

These introuduce the following changes:
* Outdoor usage for 5150-5250 and 5250-5350 MHz ranges is permitted
* 5150-5250 MHz range TPC requirment was dropped and power output raised to 200mW

OD-85a: https://www.hakom.hr/UserDocsImages/op%C4%87e%20dozvole%20prosinac%202009.g/Opca_dozvola_85a.pdf
OD-86a: https://www.hakom.hr/UserDocsImages/op%C4%87e%20dozvole%20prosinac%202009.g/Opca_dozvola_86a.pdf

Signed-off-by: Robert Marko <robert.marko@xxxxxxxxxx>
Cc: Luka Perkov <luka.perkov@xxxxxxxxxx>
---
 db.txt | 4 ++--
 1 file changed, 2 insertions(+), 2 deletions(-)

diff --git a/db.txt b/db.txt
index ac32483..52d0fab 100644
--- a/db.txt
+++ b/db.txt
@@ -693,8 +693,8 @@ country HR: DFS-ETSI
 # Harmonized CEPT countries (July 2019): https://www.ecodocdb.dk/download/25c41779-cd6e/Rec7003e.pdf
 # HR: http://tablice.hakom.hr:8080/vis?lang=en
 	(2400 - 2483.5 @ 40), (100 mW)
-	(5150 - 5250 @ 80), (200 mW), NO-OUTDOOR, AUTO-BW, wmmrule=ETSI
-	(5250 - 5350 @ 80), (100 mW), NO-OUTDOOR, DFS, AUTO-BW, wmmrule=ETSI
+	(5150 - 5250 @ 80), (200 mW), AUTO-BW, wmmrule=ETSI
+	(5250 - 5350 @ 80), (200 mW), DFS, AUTO-BW, wmmrule=ETSI
 	(5470 - 5725 @ 160), (500 mW), DFS, wmmrule=ETSI
 	# short range devices (ETSI EN 300 440-1)
 	(5725 - 5875 @ 80), (25 mW)
-- 