Croatian Regulatory Authority for Network Industries (HAKOM) has updated the general licenses OD-85 and OD-86 with the new OD-85a and OD-86a versions. These introuduce the following changes: * Outdoor usage for 5150-5250 and 5250-5350 MHz ranges is permitted * 5150-5250 MHz range TPC requirment was dropped and power output raised to 200mW OD-85a: https://www.hakom.hr/UserDocsImages/op%C4%87e%20dozvole%20prosinac%202009.g/Opca_dozvola_85a.pdf OD-86a: https://www.hakom.hr/UserDocsImages/op%C4%87e%20dozvole%20prosinac%202009.g/Opca_dozvola_86a.pdf Signed-off-by: Robert Marko <robert.marko@xxxxxxxxxx> Cc: Luka Perkov <luka.perkov@xxxxxxxxxx> --- db.txt | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/db.txt b/db.txt index ac32483..52d0fab 100644 --- a/db.txt +++ b/db.txt @@ -693,8 +693,8 @@ country HR: DFS-ETSI # Harmonized CEPT countries (July 2019): https://www.ecodocdb.dk/download/25c41779-cd6e/Rec7003e.pdf # HR: http://tablice.hakom.hr:8080/vis?lang=en (2400 - 2483.5 @ 40), (100 mW) - (5150 - 5250 @ 80), (200 mW), NO-OUTDOOR, AUTO-BW, wmmrule=ETSI - (5250 - 5350 @ 80), (100 mW), NO-OUTDOOR, DFS, AUTO-BW, wmmrule=ETSI + (5150 - 5250 @ 80), (200 mW), AUTO-BW, wmmrule=ETSI + (5250 - 5350 @ 80), (200 mW), DFS, AUTO-BW, wmmrule=ETSI (5470 - 5725 @ 160), (500 mW), DFS, wmmrule=ETSI # short range devices (ETSI EN 300 440-1) (5725 - 5875 @ 80), (25 mW) -- 2.26.2 _______________________________________________ wireless-regdb mailing list wireless-regdb@xxxxxxxxxxxxxxxxxxx http://lists.infradead.org/mailman/listinfo/wireless-regdb