On 02/21/2013 12:40 PM, Teemu Suikki wrote:
...
... With GotoXX patch, the positioning DiSEqC code
is actually just "G" for each satellite, so there is no difference to be
found there!
...
Hi,
your opinion is right for diseqc installations with only motor. But it
could be also combined with commited and uncommited switches.
I'm using 2 dish installation, one fixed multifeed with 5 LNB's and
second dish on motor with one LNB. In my installation there are 3
switches in cascade - first switch is 2 input uncommited with 2 4-input
commited switches connected to uncommited switch. The motor is between
DVB card and uncommited switch to prevent high current flow through
diseqc switches.
For any of fixed LNB the diseqc.conf looks like (example for LNB on C
input of commited switch connected to 1st input of uncommited switch)
S23.5E 11700 V 9750 t v W15 [E0 10 39 F0] W15 [E0 10 38 F8] W15 t
S23.5E 99999 V 10600 t v W15 [E0 10 39 F0] W15 [E0 10 38 F9] W15 T
S23.5E 11700 H 9750 t V W15 [E0 10 39 F0] W15 [E0 10 38 FA] W15 t
S23.5E 99999 H 10600 t V W15 [E0 10 39 F0] W15 [E0 10 38 FB] W15 T
For LNB on motorized dish it could look like
S7W 11700 V 9750 t v W15 [E0 10 39 F1] W15 [E0 10 38 FC] V G W15 v t
S7W 99999 V 10600 t v W15 [E0 10 39 F1] W15 [E0 10 38 FD] V G W15 v T
S7W 11700 H 9750 t V W15 [E0 10 39 F1] W15 [E0 10 38 FE] V G W15 V t
S7W 99999 H 10600 t V W15 [E0 10 39 F1] W15 [E0 10 38 FF] V G W15 V T
(remark that output of motorized LNB is connected to D input of commited
switch connected to second input of uncommited switch).
So practically every combination of switches and motor is possible to use.
Best Regards,
Ales
_______________________________________________
vdr mailing list
vdr@xxxxxxxxxxx
http://www.linuxtv.org/cgi-bin/mailman/listinfo/vdr