Am 14.11.2010 12:07, schrieb LuboÅ DoleÅel: > Aside from that I don't understand why it terminates completely if it > _thinks_ some bad data arrived. Data errors may happen at any time and > it's not a valid reason for an emergency exit. To clarify this: The emergency exit is triggered if and only if a recording did not record any (not a single byte of) data within 30 seconds. I think this is a valid criteria for an emergency. In your case, as Klaus already wrote, it may have something to do with the fact that VDR wants to start the recording with an I-frame, and probably can't find one. Cheers, Udo _______________________________________________ vdr mailing list vdr@xxxxxxxxxxx http://www.linuxtv.org/cgi-bin/mailman/listinfo/vdr