Traditionally Linux used ttyO as console name for Omap devices. This has been changed to ttyS in 2014. Since then ttyO gets translated to ttyS by the Kernel. Use ttyS directly to avoid the translation in the Kernel. Signed-off-by: Sascha Hauer <s.hauer@xxxxxxxxxxxxxx> --- drivers/serial/serial_ns16550.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/drivers/serial/serial_ns16550.c b/drivers/serial/serial_ns16550.c index 45341d1c9b..56a1c6c6b9 100644 --- a/drivers/serial/serial_ns16550.c +++ b/drivers/serial/serial_ns16550.c @@ -402,13 +402,13 @@ static struct ns16550_drvdata ns16550_drvdata = { static __maybe_unused struct ns16550_drvdata omap_drvdata = { .init_port = ns16550_omap_init_port, - .linux_console_name = "ttyO", + .linux_console_name = "ttyS", .linux_earlycon_name = "omap8250", }; static __maybe_unused struct ns16550_drvdata omap_clk48m_drvdata = { .init_port = ns16550_omap_init_port, - .linux_console_name = "ttyO", + .linux_console_name = "ttyS", .clk_default = 48000000, }; -- 2.39.5