On Thu, Nov 09, 2023 at 01:10:12PM +0100, Ahmad Fatoum wrote: > On the STM32MP1, shutting down barebox can result in a > > ERROR: phy1: phy exit failed --> -22 > > message printed to the console. This is because the regulator is disabled > more often than it was enabled, because stm32_usbphyc_pll_disable > is called twice: > > - Once from stm32_usbphyc_remove calling stm32_usbphyc_phy_exit > - Once from dwc2_remove calling phy_exit -> stm32_usbphyc_phy_exit > > The code is taken from Linux and likely causes no issues there, because > devices are removed in reverse probe order, which barebox doesn't > enforce. Properly solving this would be a larger endeavour, so for now > just fix the stm32-usbphyc driver to ignore reference count dropping > below zero and only call __stm32_usbphyc_pll_disable once. > > Signed-off-by: Ahmad Fatoum <a.fatoum@xxxxxxxxxxxxxx> > --- > drivers/phy/phy-stm32-usbphyc.c | 2 +- > 1 file changed, 1 insertion(+), 1 deletion(-) Applied, thanks Sascha > > diff --git a/drivers/phy/phy-stm32-usbphyc.c b/drivers/phy/phy-stm32-usbphyc.c > index ac82b019f44c..91f4e7f7e08d 100644 > --- a/drivers/phy/phy-stm32-usbphyc.c > +++ b/drivers/phy/phy-stm32-usbphyc.c > @@ -277,7 +277,7 @@ static int __stm32_usbphyc_pll_disable(struct stm32_usbphyc *usbphyc) > static int stm32_usbphyc_pll_disable(struct stm32_usbphyc *usbphyc) > { > /* Check if a phy port is still active or clk48 in use */ > - if (atomic_dec_return(&usbphyc->n_pll_cons) > 0) > + if (atomic_dec_return(&usbphyc->n_pll_cons) != 1) > return 0; > > return __stm32_usbphyc_pll_disable(usbphyc); > -- > 2.39.2 > > > -- Pengutronix e.K. | | Steuerwalder Str. 21 | http://www.pengutronix.de/ | 31137 Hildesheim, Germany | Phone: +49-5121-206917-0 | Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 |