On Wed, Aug 25, 2021 at 08:55:54AM +0200, Rouven Czerwinski wrote: > Currently barebox will try to talk to the phy over mdio, even if the > parent is a fixed-link. This will result in the following stacktrace: > > barebox@Linux Automation Test Automation Controller (TAC):/ dhcp > unable to handle NULL pointer dereference at address 0x00000130 > pc : [<dfc01800>] lr : [<dfc0f963>] > sp : dffefd40 ip : 004c4b40 fp : d00286e0 > r10: cf25cc4e r9 : 00000000 r8 : 05f5e100 > r7 : 00000130 r6 : 00000000 r5 : 00000000 r4 : 00000130 > r3 : 00000109 r2 : 00000000 r1 : 00000000 r0 : 00000130 > Flags: nZCv IRQs off FIQs off Mode SVC_32 > WARNING: [<dfc01800>] (slice_acquire+0xc/0x28) from [<dfc0f963>] (mdiobus_read+0x13/0x28) > WARNING: [<dfc0f963>] (mdiobus_read+0x13/0x28) from [<dfc10685>] (eqos_start+0x85/0x32c) > WARNING: [<dfc10685>] (eqos_start+0x85/0x32c) from [<dfc3cdf1>] (eth_open+0xd/0x24) > WARNING: [<dfc3cdf1>] (eth_open+0xd/0x24) from [<dfc3e391>] (dhcp+0xb/0x3a) > WARNING: [<dfc3e391>] (dhcp+0xb/0x3a) from [<dfc30fab>] (do_dhcp+0xfb/0x114) > WARNING: [<dfc30fab>] (do_dhcp+0xfb/0x114) from [<dfc0490f>] (execute_command+0x23/0x4c) > WARNING: [<dfc0490f>] (execute_command+0x23/0x4c) from [<dfc0a127>] (run_list_real+0x5bf/0x638) > WARNING: [<dfc0a127>] (run_list_real+0x5bf/0x638) from [<dfc09a2b>] (parse_stream_outer+0xc7/0x154) > WARNING: [<dfc09a2b>] (parse_stream_outer+0xc7/0x154) from [<dfc0a383>] (run_shell+0x3f/0x6c) > WARNING: [<dfc0a383>] (run_shell+0x3f/0x6c) from [<dfc010b9>] (run_init+0x191/0x200) > WARNING: [<dfc010b9>] (run_init+0x191/0x200) from [<dfc01153>] (start_barebox+0x2b/0x6c) > WARNING: [<dfc01153>] (start_barebox+0x2b/0x6c) from [<dfc4be6d>] (barebox_non_pbl_start+0x121/0x164) > WARNING: [<dfc4be6d>] (barebox_non_pbl_start+0x121/0x164) from [<dfc00005>] (__bare_init_start+0x1/0xc) > > WARNING: [<dfc4da7d>] (unwind_backtrace+0x1/0x78) from [<dfc01461>] (panic+0x1d/0x34) > WARNING: [<dfc01461>] (panic+0x1d/0x34) from [<dfc4b6a3>] (do_exception+0xf/0x14) > WARNING: [<dfc4b6a3>] (do_exception+0xf/0x14) from [<dfc4b711>] (do_data_abort+0x21/0x34) > WARNING: [<dfc4b711>] (do_data_abort+0x21/0x34) from [<dfc4b454>] (do_abort_6+0x48/0x54) > > Simply return with 0 if bus is zero which indicates that the phy is > connected to a fixed link. > > Signed-off-by: Rouven Czerwinski <r.czerwinski@xxxxxxxxxxxxxx> > --- > drivers/net/designware_eqos.c | 4 ++++ > 1 file changed, 4 insertions(+) Applied, thanks Sascha -- Pengutronix e.K. | | Steuerwalder Str. 21 | http://www.pengutronix.de/ | 31137 Hildesheim, Germany | Phone: +49-5121-206917-0 | Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 | _______________________________________________ barebox mailing list barebox@xxxxxxxxxxxxxxxxxxx http://lists.infradead.org/mailman/listinfo/barebox