Hi, On 31.05.21 11:50, Sascha Hauer wrote: > On Mon, May 31, 2021 at 09:13:19AM +0200, Ahmad Fatoum wrote: >> Some barebox ports may have a watchdog, but no restart handler, e.g. >> reset happens via PMIC, which has no driver yet, but watchdog controls >> reset line going to PMIC. Accommodate such setups by allowing >> registration of watchdog as fall back restart handler. >> >> As reset handling can't be disabled, this is made a default n option >> to conserve binary size unless explicitly enabled. > > Do we really need to make this optional? The binary size overhead can't > be much more than a few bytes. I wouldn't like, if after an update, reset silently fell back to the watchdog instead of hanging and alerting the user that something broke. For development, it's ok, but once I have a proper reset driver, I want either that or an error message IMO. Cheers, Ahmad > > Sascha > > -- Pengutronix e.K. | | Steuerwalder Str. 21 | http://www.pengutronix.de/ | 31137 Hildesheim, Germany | Phone: +49-5121-206917-0 | Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 | _______________________________________________ barebox mailing list barebox@xxxxxxxxxxxxxxxxxxx http://lists.infradead.org/mailman/listinfo/barebox