On Wed, May 19, 2021 at 09:38:54AM +0200, Michael Tretter wrote: > Only READ data transfers actually send a data available interrupt. > Therefore, check if the transfer is a read and wait for the data only in > this case. > > Signed-off-by: Michael Tretter <m.tretter@xxxxxxxxxxxxxx> > --- > > Hi Michael, > > On Tue, 18 May 2021 08:09:47 +0000, Michael Graichen wrote: > > > This looks familiar. I have a similar patch that sets SDHCI_INT_DATA_AVAIL > > > only if the command is a READ, but I didn't yet have time to verify, that this > > > is the correct fix. > > > > Can you please send it to me? > > Here you are. I am not sure, if the fix is correct. I also added another > patch to handle situations where data is NULL, but I am not entirely sure > about that one either. > > Michael > --- > drivers/mci/arasan-sdhci.c | 2 +- > 1 file changed, 1 insertion(+), 1 deletion(-) > > diff --git a/drivers/mci/arasan-sdhci.c b/drivers/mci/arasan-sdhci.c > index 520bf30ff952..399966e8cf10 100644 > --- a/drivers/mci/arasan-sdhci.c > +++ b/drivers/mci/arasan-sdhci.c > @@ -277,7 +277,7 @@ static int arasan_sdhci_send_cmd(struct mci_host *mci, struct mci_cmd *cmd, > sdhci_write32(&host->sdhci, SDHCI_INT_STATUS, ~0); > > mask = SDHCI_INT_CMD_COMPLETE; > - if (data) > + if (data && data->flags == MMC_DATA_READ) > mask |= SDHCI_INT_DATA_AVAIL; Waiting for Data avaialable only makes sense when reading. Applied, thanks Sascha -- Pengutronix e.K. | | Steuerwalder Str. 21 | http://www.pengutronix.de/ | 31137 Hildesheim, Germany | Phone: +49-5121-206917-0 | Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 | _______________________________________________ barebox mailing list barebox@xxxxxxxxxxxxxxxxxxx http://lists.infradead.org/mailman/listinfo/barebox