Re: [PATCH] net: phy: micrel: backport ksz9031 125MHz ref-clk workaround

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On Mon, Feb 11, 2019 at 05:44:00PM +0100, Marco Felsch wrote:
> This patch backports linux commit e1b505a60366 ("net: phy: micrel: add
> 125MHz reference clock workaround").
> 
> 8<--------------------- The original commit message -------------------
> 
> net: phy: micrel: add 125MHz reference clock workaround
> 
> The micrel KSZ9031 phy has a optional clock pin (CLK125_NDO) which can be
> used as reference clock for the MAC unit. The clock signal must meet the
> RGMII requirements to ensure the correct data transmission between the
> MAC and the PHY. The KSZ9031 phy does not fulfill the duty cycle
> requirement if the phy is configured as slave. For a complete
> describtion look at the errata sheets: DS80000691D or DS80000692D.
> 
> The errata sheet recommends to force the phy into master mode whenever
> there is a 1000Base-T link-up as work around. Only set the
> "micrel,force-master" property if you use the phy reference clock provided
> by CLK125_NDO pin as MAC reference clock in your application.
> 
> Attenation, this workaround is only usable if the link partner can
> be configured to slave mode for 1000Base-T.
> 
> Signed-off-by: Markus Niebel <Markus.Niebel@xxxxxx>
> [m.felsch@xxxxxxxxxxxxxx: fix dt-binding documentation]
> [m.felsch@xxxxxxxxxxxxxx: use already existing result var for read/write]
> [m.felsch@xxxxxxxxxxxxxx: add error handling]
> [m.felsch@xxxxxxxxxxxxxx: add more comments]
> Signed-off-by: Marco Felsch <m.felsch@xxxxxxxxxxxxxx>
> Reviewed-by: Andrew Lunn <andrew@xxxxxxx>
> Signed-off-by: David S. Miller <davem@xxxxxxxxxxxxx>
> 8<---------------------------------------------------------------------
> 
> Signed-off-by: Marco Felsch <m.felsch@xxxxxxxxxxxxxx>
> ---

Applied, thanks

Sascha

-- 
Pengutronix e.K.                           |                             |
Industrial Linux Solutions                 | http://www.pengutronix.de/  |
Peiner Str. 6-8, 31137 Hildesheim, Germany | Phone: +49-5121-206917-0    |
Amtsgericht Hildesheim, HRA 2686           | Fax:   +49-5121-206917-5555 |

_______________________________________________
barebox mailing list
barebox@xxxxxxxxxxxxxxxxxxx
http://lists.infradead.org/mailman/listinfo/barebox