This is the default out-of-reset voltage, but if only the i.MX6 SoC got reset, the PMIC might still be stuck at the lower volatge for the slow operating point. Signed-off-by: Lucas Stach <l.stach@xxxxxxxxxxxxxx> --- arch/arm/boards/zii-imx6q-rdu2/board.c | 17 +++++++++++++++++ 1 file changed, 17 insertions(+) diff --git a/arch/arm/boards/zii-imx6q-rdu2/board.c b/arch/arm/boards/zii-imx6q-rdu2/board.c index f6c908c9f16d..bce221bf8d20 100644 --- a/arch/arm/boards/zii-imx6q-rdu2/board.c +++ b/arch/arm/boards/zii-imx6q-rdu2/board.c @@ -137,10 +137,27 @@ late_initcall(rdu2_enable_front_panel_usb); static int rdu2_devices_init(void) { + struct i2c_client client; + if (!of_machine_is_compatible("zii,imx6q-zii-rdu2") && !of_machine_is_compatible("zii,imx6qp-zii-rdu2")) return 0; + client.adapter = i2c_get_adapter(1); + if (client.adapter) { + u8 reg; + + /* + * Reset PMIC SW1AB and SW1C rails to 1.375V. If an event + * caused only the i.MX6 SoC reset, the PMIC might still be + * stuck on the low voltage for the slow operating point. + */ + client.addr = 0x08; /* PMIC i2c address */ + reg = 0x2b; /* 1.375V, valid for both rails */ + i2c_write_reg(&client, 0x20, ®, 1); + i2c_write_reg(&client, 0x2e, ®, 1); + } + barebox_set_hostname("rdu2"); imx6_bbu_internal_spi_i2c_register_handler("SPI", "/dev/m25p0.barebox", -- 2.19.0 _______________________________________________ barebox mailing list barebox@xxxxxxxxxxxxxxxxxxx http://lists.infradead.org/mailman/listinfo/barebox