When probing from an upstream DT, we don't always have influence on how many timer instances are enabled. Just use the first one and silently skip the other instances. Signed-off-by: Lucas Stach <l.stach@xxxxxxxxxxxxxx> --- drivers/clocksource/amba-sp804.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/drivers/clocksource/amba-sp804.c b/drivers/clocksource/amba-sp804.c index c5ad9947cd96..66e3988b4cf8 100644 --- a/drivers/clocksource/amba-sp804.c +++ b/drivers/clocksource/amba-sp804.c @@ -35,8 +35,8 @@ static int sp804_probe(struct amba_device *dev, const struct amba_id *id) int ret; if (sp804_base) { - dev_err(&dev->dev, "single instance driver\n"); - return -EBUSY; + dev_dbg(&dev->dev, "skipping secondary instance\n"); + return 0; } sp804_clk = clk_get(&dev->dev, NULL); -- 2.11.0 _______________________________________________ barebox mailing list barebox@xxxxxxxxxxxxxxxxxxx http://lists.infradead.org/mailman/listinfo/barebox