On Sat, Jul 13, 2013 at 09:31:40AM +0400, Alexander Shiyan wrote: > Buffer for RX is set incorrectly. > > barebox@Phytec phyCORE-i.MX27:/ spi -r 128 -v > device config > bus_num = 0 > max_speed_hz = 1000000 > chip_select = 0 > mode = 0x0 > bits_per_word = 8 > > wrote 0 bytes > 00000000: > read 128 bytes > 00000000: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ................ > 00000010: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ................ > 00000020: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ................ > 00000030: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ................ > 00000040: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ................ > 00000050: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ................ > 00000060: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ................ > 00000070: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ................ > unable to handle paging request at address 0x4dffd3d0 > pc : [<a7f05ec4>] lr : [<a7f05ebc>] > sp : a7fff890 ip : a7fff860 fp : a7f68820 > r10: a6ffe9bc r9 : 00000000 r8 : 00000001 > r7 : a6ffe9ec r6 : a6f00000 r5 : a6ffe9ec r4 : a6ffe9e4 > r3 : a6ffe9e4 r2 : a6ffe9e5 r1 : a6ffe9e4 r0 : 4dffd3cc > Flags: nZCv IRQs off FIQs off Mode SVC_32 > ... > > Signed-off-by: Alexander Shiyan <shc_work@xxxxxxx> Applied, thanks Sascha -- Pengutronix e.K. | | Industrial Linux Solutions | http://www.pengutronix.de/ | Peiner Str. 6-8, 31137 Hildesheim, Germany | Phone: +49-5121-206917-0 | Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 | _______________________________________________ barebox mailing list barebox@xxxxxxxxxxxxxxxxxxx http://lists.infradead.org/mailman/listinfo/barebox