Re: Can VPD Unit Serial Number be persistent?

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 07/27/2014 05:55 PM, Lee Duncan wrote:
On 07/25/2014 04:46 PM, Lee Duncan wrote:
Hi:

I am creating an iSCSI LUNs using iblock back end storage.

I notice that my VPD Unit Serial Number is different each time my server
reboots. That does not seem right.

I take it by the lack of response that this is either an issue that has
been discussed before, or one that nobody else cares about?

Or it was the weekend :)

In my case, this bug means that when my target nodes reboot and I get
new Serial Numbers the cluster using that node as part of a logical
volume cannot find it.

I will work on a patch for submission.

Yup. BTW this is a user tools (rtslib and/or targetcli) issue, not kernel code. The issue is not present in targetcli-fb.

Regards -- Andy

--
To unsubscribe from this list: send the line "unsubscribe target-devel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html




[Index of Archives]     [Linux SCSI]     [Kernel Newbies]     [Linux SCSI Target Infrastructure]     [Share Photos]     [IDE]     [Security]     [Git]     [Netfilter]     [Bugtraq]     [Yosemite News]     [MIPS Linux]     [ARM Linux]     [Linux Security]     [Linux RAID]     [Linux ATA RAID]     [Linux IIO]     [Device Mapper]