On Tue, Jun 10, 2014 at 2:50 AM, Christophe Vu-Brugier <cvubrugier@xxxxxxxx> wrote: > In INQUIRY, one test complains that "the Unit serial number length > (41) does not match transfer length (255)." Another test fails because > the Windows Certification Kit expects an "iSCSI version descriptor" > (0x0960) in the list of version descriptors. > > Several failures reported for MODE SENSE and MODE SELECT look the > same: the length of the transferred data is greater than the length > stored in the CDB. Thanks for the report. I think I have local changes I've been meaning to send out that should address this. Please look out for two patches coming shortly that I think deal with this (and give a framework for fixing other similar issues). - R. -- To unsubscribe from this list: send the line "unsubscribe target-devel" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html