4.0-stable review patch. If anyone has any objections, please let me know. ------------------ From: Eric Wong <normalperson@xxxxxxxx> commit 2f80b2958abe5658000d5ad9b45a36ecf879666e upstream. This quirk allows us to avoid the noisy: current rate 0 is different from the runtime rate message every time playback starts. While USB DAC in the RR2150 supports reading the sample rate, it never returns a sample rate other than zero in my observation with common sample rates. Signed-off-by: Eric Wong <normalperson@xxxxxxxx> Cc: Joe Turner <joe@xxxxxxxxxxx> Signed-off-by: Takashi Iwai <tiwai@xxxxxxx> Signed-off-by: Greg Kroah-Hartman <gregkh@xxxxxxxxxxxxxxxxxxx> --- sound/usb/quirks.c | 1 + 1 file changed, 1 insertion(+) --- a/sound/usb/quirks.c +++ b/sound/usb/quirks.c @@ -1120,6 +1120,7 @@ bool snd_usb_get_sample_rate_quirk(struc case USB_ID(0x045E, 0x0772): /* MS Lifecam Studio */ case USB_ID(0x045E, 0x0779): /* MS Lifecam HD-3000 */ case USB_ID(0x04D8, 0xFEEA): /* Benchmark DAC1 Pre */ + case USB_ID(0x074D, 0x3553): /* Outlaw RR2150 (Micronas UAC3553B) */ return true; } return false; -- To unsubscribe from this list: send the line "unsubscribe stable" in