6.1-stable review patch. If anyone has any objections, please let me know. ------------------ From: Javier Carrasco <javier.carrasco.cruz@xxxxxxxxx> commit c9e9746f275c45108f2b0633a4855d65d9ae0736 upstream. The driver still uses the sensor resolution provided in the datasheet until Rev. 1.6, 28-Apr-2022, which was updated with Rev 1.7, 28-Nov-2023. The original ambient light resolution has been updated from 0.0036 lx/ct to 0.0042 lx/ct, which is the value that can be found in the current device datasheet. Update the default resolution for IT = 100 ms and GAIN = 1/8 from the original 4608 mlux/cnt to the current value from the "Resolution and maximum detection range" table (Application Note 84367, page 5), 5376 mlux/cnt. Cc: <stable@xxxxxxxxxxxxxxx> Fixes: 7b779f573c48 ("iio: light: add driver for veml6030 ambient light sensor") Signed-off-by: Javier Carrasco <javier.carrasco.cruz@xxxxxxxxx> Link: https://patch.msgid.link/20240923-veml6035-v2-1-58c72a0df31c@xxxxxxxxx Signed-off-by: Jonathan Cameron <Jonathan.Cameron@xxxxxxxxxx> Signed-off-by: Greg Kroah-Hartman <gregkh@xxxxxxxxxxxxxxxxxxx> --- drivers/iio/light/veml6030.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) --- a/drivers/iio/light/veml6030.c +++ b/drivers/iio/light/veml6030.c @@ -780,7 +780,7 @@ static int veml6030_hw_init(struct iio_d /* Cache currently active measurement parameters */ data->cur_gain = 3; - data->cur_resolution = 4608; + data->cur_resolution = 5376; data->cur_integration_time = 3; return ret;