RE: [PATCH] tpm,tpm_tis: Avoid warning splat at shutdown

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



> From: Lino Sanfilippo <l.sanfilippo@xxxxxxxxxx>
> Sent: Thursday, February 1, 2024 5:37 AM
> Subject: [PATCH] tpm,tpm_tis: Avoid warning splat at shutdown
> 
> If interrupts are not activated the work struct 'free_irq_work' is not
> initialized. This results in a warning splat at module shutdown.
> 
> Fix this by always initializing the work regardless of whether interrupts
> are activated or not.

That's using flush_work(), which just waits for one to complete. Is there
any case where multiple work entries could be queued, and cancel_work_sync() 
would be necessary?

tpm_tis_probe_irq() has a loop calling tpm_tis_probe_irq_single()
for 3 to 15. Could each of those could trigger an interrupt storm and
call tpm_tis_revert_interrupts(), which calls schedule_work()?