[PATCH 6.4 133/737] thermal/of: Fix potential uninitialized value access

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



6.4-stable review patch.  If anyone has any objections, please let me know.

------------------

From: Peng Fan <peng.fan@xxxxxxx>

[ Upstream commit f96801f0cfcefc0a16b146596577c53c75ee9773 ]

If of_parse_phandle_with_args() called from __thermal_of_bind() or
__thermal_of_unbind() fails, cooling_spec.np will not be initialized,
so move the of_node_put() calls below the respective return value checks
to avoid dereferencing an uninitialized pointer.

Fixes: 3fd6d6e2b4e8 ("thermal/of: Rework the thermal device tree initialization")
Signed-off-by: Peng Fan <peng.fan@xxxxxxx>
[ rjw: Subject and changelog edits ]
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@xxxxxxxxx>
Signed-off-by: Sasha Levin <sashal@xxxxxxxxxx>
---
 drivers/thermal/thermal_of.c | 8 ++++----
 1 file changed, 4 insertions(+), 4 deletions(-)

diff --git a/drivers/thermal/thermal_of.c b/drivers/thermal/thermal_of.c
index bc07ae1c284cf..22272f9c5934a 100644
--- a/drivers/thermal/thermal_of.c
+++ b/drivers/thermal/thermal_of.c
@@ -292,13 +292,13 @@ static int __thermal_of_unbind(struct device_node *map_np, int index, int trip_i
 	ret = of_parse_phandle_with_args(map_np, "cooling-device", "#cooling-cells",
 					 index, &cooling_spec);
 
-	of_node_put(cooling_spec.np);
-
 	if (ret < 0) {
 		pr_err("Invalid cooling-device entry\n");
 		return ret;
 	}
 
+	of_node_put(cooling_spec.np);
+
 	if (cooling_spec.args_count < 2) {
 		pr_err("wrong reference to cooling device, missing limits\n");
 		return -EINVAL;
@@ -325,13 +325,13 @@ static int __thermal_of_bind(struct device_node *map_np, int index, int trip_id,
 	ret = of_parse_phandle_with_args(map_np, "cooling-device", "#cooling-cells",
 					 index, &cooling_spec);
 
-	of_node_put(cooling_spec.np);
-
 	if (ret < 0) {
 		pr_err("Invalid cooling-device entry\n");
 		return ret;
 	}
 
+	of_node_put(cooling_spec.np);
+
 	if (cooling_spec.args_count < 2) {
 		pr_err("wrong reference to cooling device, missing limits\n");
 		return -EINVAL;
-- 
2.40.1






[Index of Archives]     [Linux Kernel]     [Kernel Development Newbies]     [Linux USB Devel]     [Video for Linux]     [Linux Audio Users]     [Yosemite Hiking]     [Linux Kernel]     [Linux SCSI]

  Powered by Linux