From: Kees Jan Koster <kjkoster@xxxxxxxxxxxx> commit 71f8afa2b66e356f435b6141b4a9ccf953e18356 upstream. The Silicon Labs IFS-USB-DATACABLE is used in conjunction with for example the Quint UPSes. It is used to enable Modbus communication with the UPS to query configuration, power and battery status. Signed-off-by: Kees Jan Koster <kjkoster@xxxxxxxxxxxx> Cc: stable@xxxxxxxxxxxxxxx Signed-off-by: Johan Hovold <johan@xxxxxxxxxx> Signed-off-by: Greg Kroah-Hartman <gregkh@xxxxxxxxxxxxxxxxxxx> --- drivers/usb/serial/cp210x.c | 1 + 1 file changed, 1 insertion(+) --- a/drivers/usb/serial/cp210x.c +++ b/drivers/usb/serial/cp210x.c @@ -120,6 +120,7 @@ static const struct usb_device_id id_tab { USB_DEVICE(0x10C4, 0x826B) }, /* Cygnal Integrated Products, Inc., Fasttrax GPS demonstration module */ { USB_DEVICE(0x10C4, 0x8281) }, /* Nanotec Plug & Drive */ { USB_DEVICE(0x10C4, 0x8293) }, /* Telegesis ETRX2USB */ + { USB_DEVICE(0x10C4, 0x82AA) }, /* Silicon Labs IFS-USB-DATACABLE used with Quint UPS */ { USB_DEVICE(0x10C4, 0x82EF) }, /* CESINEL FALCO 6105 AC Power Supply */ { USB_DEVICE(0x10C4, 0x82F1) }, /* CESINEL MEDCAL EFD Earth Fault Detector */ { USB_DEVICE(0x10C4, 0x82F2) }, /* CESINEL MEDCAL ST Network Analyzer */