From: Mark Zhang <markzhang@xxxxxxxxxx> [ Upstream commit ecacb3751f254572af0009b9501e2cdc83a30b6a ] When filling a cm_id entry, return "-EAGAIN" instead of 0 if the cm_id doesn'the have the same port as requested, otherwise an incomplete entry may be returned, which causes "rdam res show cm_id" to return an error. For example on a machine with two rdma devices with "rping -C 1 -v -s" running background, the "rdma" command fails: $ rdma -V rdma utility, iproute2-5.19.0 $ rdma res show cm_id link mlx5_0/- cm-idn 0 state LISTEN ps TCP pid 28056 comm rping src-addr 0.0.0.0:7174 error: Protocol not available While with this fix it succeeds: $ rdma res show cm_id link mlx5_0/- cm-idn 0 state LISTEN ps TCP pid 26395 comm rping src-addr 0.0.0.0:7174 link mlx5_1/- cm-idn 0 state LISTEN ps TCP pid 26395 comm rping src-addr 0.0.0.0:7174 Fixes: 00313983cda6 ("RDMA/nldev: provide detailed CM_ID information") Signed-off-by: Mark Zhang <markzhang@xxxxxxxxxx> Link: https://lore.kernel.org/r/a08e898cdac5e28428eb749a99d9d981571b8ea7.1667810736.git.leonro@xxxxxxxxxx Signed-off-by: Leon Romanovsky <leon@xxxxxxxxxx> Signed-off-by: Sasha Levin <sashal@xxxxxxxxxx> --- drivers/infiniband/core/nldev.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/drivers/infiniband/core/nldev.c b/drivers/infiniband/core/nldev.c index cd89e59cbe33..6f3799698634 100644 --- a/drivers/infiniband/core/nldev.c +++ b/drivers/infiniband/core/nldev.c @@ -550,7 +550,7 @@ static int fill_res_cm_id_entry(struct sk_buff *msg, bool has_cap_net_admin, struct rdma_cm_id *cm_id = &id_priv->id; if (port && port != cm_id->port_num) - return 0; + return -EAGAIN; if (cm_id->port_num && nla_put_u32(msg, RDMA_NLDEV_ATTR_PORT_INDEX, cm_id->port_num)) -- 2.35.1