When the driver is unloaded or when the system goes into standby mode, DeInitLed871x is called to stop the led layer. In this case, we stop the blinking worker but we do not switch the led off explicitly. On my system, I can go into standby mode with the LED enabled. Add a call to SwLedOff to fix this. Cc: stable@xxxxxxxxxxxxxxx Fixes: 15865124feed ("staging: r8188eu: introduce new core dir for RTL8188eu driver") Signed-off-by: Martin Kaiser <martin@xxxxxxxxx> --- drivers/staging/r8188eu/core/rtw_led.c | 1 + 1 file changed, 1 insertion(+) diff --git a/drivers/staging/r8188eu/core/rtw_led.c b/drivers/staging/r8188eu/core/rtw_led.c index e1be1ba189cb..25fab7bce7dc 100644 --- a/drivers/staging/r8188eu/core/rtw_led.c +++ b/drivers/staging/r8188eu/core/rtw_led.c @@ -41,6 +41,7 @@ void DeInitLed871x(struct LED_871x *pLed) { cancel_delayed_work_sync(&pLed->blink_work); ResetLedStatus(pLed); + SwLedOff(pLed->padapter, pLed); } static void SwLedBlink1(struct LED_871x *pLed) -- 2.30.2