From: Davide Caratti <dcaratti@xxxxxxxxxx> [ Upstream commit 05ff8435e50569a0a6b95e5ceaea43696e8827ab ] modern userspace applications, like OVN, can configure the TC datapath to "recirculate" packets several times. If more than 4 "recirculation" rules are configured, packets can be dropped by __tcf_classify(). Changing the maximum number of reclassifications (from 4 to 16) should be sufficient to prevent drops in most use cases, and guard against loops at the same time. Signed-off-by: Davide Caratti <dcaratti@xxxxxxxxxx> Signed-off-by: David S. Miller <davem@xxxxxxxxxxxxx> Signed-off-by: Sasha Levin <sashal@xxxxxxxxxx> --- net/sched/cls_api.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/net/sched/cls_api.c b/net/sched/cls_api.c index 279f9e2a2319..d73b5c5514a9 100644 --- a/net/sched/cls_api.c +++ b/net/sched/cls_api.c @@ -1531,7 +1531,7 @@ static inline int __tcf_classify(struct sk_buff *skb, u32 *last_executed_chain) { #ifdef CONFIG_NET_CLS_ACT - const int max_reclassify_loop = 4; + const int max_reclassify_loop = 16; const struct tcf_proto *first_tp; int limit = 0; -- 2.30.2