From: Vadim Pasternak <vadimp@xxxxxxxxxx> [ Upstream commit 57726ebe2733891c9f59105eff028735f73d05fb ] Validate thresholds to avoid a single failure due to some transceiver unreliability. Ignore the last readouts in case warning temperature is above alarm temperature, since it can cause unexpected thermal shutdown. Stay with the previous values and refresh threshold within the next iteration. This is a rare scenario, but it was observed at a customer site. Fixes: 6a79507cfe94 ("mlxsw: core: Extend thermal module with per QSFP module thermal zones") Signed-off-by: Vadim Pasternak <vadimp@xxxxxxxxxx> Reviewed-by: Jiri Pirko <jiri@xxxxxxxxxx> Signed-off-by: Ido Schimmel <idosch@xxxxxxxxxx> Signed-off-by: Jakub Kicinski <kuba@xxxxxxxxxx> Signed-off-by: Greg Kroah-Hartman <gregkh@xxxxxxxxxxxxxxxxxxx> --- drivers/net/ethernet/mellanox/mlxsw/core_thermal.c | 11 +++++++---- 1 file changed, 7 insertions(+), 4 deletions(-) --- a/drivers/net/ethernet/mellanox/mlxsw/core_thermal.c +++ b/drivers/net/ethernet/mellanox/mlxsw/core_thermal.c @@ -177,6 +177,12 @@ mlxsw_thermal_module_trips_update(struct if (err) return err; + if (crit_temp > emerg_temp) { + dev_warn(dev, "%s : Critical threshold %d is above emergency threshold %d\n", + tz->tzdev->type, crit_temp, emerg_temp); + return 0; + } + /* According to the system thermal requirements, the thermal zones are * defined with four trip points. The critical and emergency * temperature thresholds, provided by QSFP module are set as "active" @@ -191,11 +197,8 @@ mlxsw_thermal_module_trips_update(struct tz->trips[MLXSW_THERMAL_TEMP_TRIP_NORM].temp = crit_temp; tz->trips[MLXSW_THERMAL_TEMP_TRIP_HIGH].temp = crit_temp; tz->trips[MLXSW_THERMAL_TEMP_TRIP_HOT].temp = emerg_temp; - if (emerg_temp > crit_temp) - tz->trips[MLXSW_THERMAL_TEMP_TRIP_CRIT].temp = emerg_temp + + tz->trips[MLXSW_THERMAL_TEMP_TRIP_CRIT].temp = emerg_temp + MLXSW_THERMAL_MODULE_TEMP_SHIFT; - else - tz->trips[MLXSW_THERMAL_TEMP_TRIP_CRIT].temp = emerg_temp; return 0; }