From: Vladyslav Tarasiuk <vladyslavt@xxxxxxxxxx> [ Upstream commit 1ce5fc724a26e0b476e42c5d588bdb80caea003b ] Currently, if user disables VFs with some min and max rates configured, they are cleared. But QoS data is not cleared and restored upon next VF enable placing limits on minimal rate for given VF, when user expects none. To match cleared vport->info struct with QoS-related min and max rates upon VF disable, clear vport->qos struct too. Fixes: 556b9d16d3f5 ("net/mlx5: Clear VF's configuration on disabling SRIOV") Signed-off-by: Vladyslav Tarasiuk <vladyslavt@xxxxxxxxxx> Reviewed-by: Moshe Shemesh <moshe@xxxxxxxxxx> Signed-off-by: Saeed Mahameed <saeedm@xxxxxxxxxx> Signed-off-by: Greg Kroah-Hartman <gregkh@xxxxxxxxxxxxxxxxxxx> --- drivers/net/ethernet/mellanox/mlx5/core/eswitch.c | 1 + 1 file changed, 1 insertion(+) --- a/drivers/net/ethernet/mellanox/mlx5/core/eswitch.c +++ b/drivers/net/ethernet/mellanox/mlx5/core/eswitch.c @@ -1408,6 +1408,7 @@ static void mlx5_eswitch_clear_vf_vports int i; mlx5_esw_for_each_vf_vport(esw, i, vport, esw->esw_funcs.num_vfs) { + memset(&vport->qos, 0, sizeof(vport->qos)); memset(&vport->info, 0, sizeof(vport->info)); vport->info.link_state = MLX5_VPORT_ADMIN_STATE_AUTO; }