From: Damien Le Moal <damien.lemoal@xxxxxxx> [ Upstream commit f025d9d9934b84cd03b7796072d10686029c408e ] The Kendryte K210 SoC CLINT is compatible with Sifive clint v0 (sifive,clint0). Fix the Kendryte K210 device tree clint entry to be inline with the sifive timer definition documented in Documentation/devicetree/bindings/timer/sifive,clint.yaml. The device tree clint entry is renamed similarly to u-boot device tree definition to improve compatibility with u-boot defined device tree. To ensure correct initialization, the interrup-cells attribute is added and the interrupt-extended attribute definition fixed. This fixes boot failures with Kendryte K210 SoC boards. Note that the clock referenced is kept as K210_CLK_ACLK, which does not necessarilly match the clint MTIME increment rate. This however does not seem to cause any problem for now. Signed-off-by: Damien Le Moal <damien.lemoal@xxxxxxx> Signed-off-by: Palmer Dabbelt <palmerdabbelt@xxxxxxxxxx> Signed-off-by: Sasha Levin <sashal@xxxxxxxxxx> --- arch/riscv/boot/dts/kendryte/k210.dtsi | 6 ++++-- 1 file changed, 4 insertions(+), 2 deletions(-) diff --git a/arch/riscv/boot/dts/kendryte/k210.dtsi b/arch/riscv/boot/dts/kendryte/k210.dtsi index c1df56ccb8d55..d2d0ff6456325 100644 --- a/arch/riscv/boot/dts/kendryte/k210.dtsi +++ b/arch/riscv/boot/dts/kendryte/k210.dtsi @@ -95,10 +95,12 @@ #clock-cells = <1>; }; - clint0: interrupt-controller@2000000 { + clint0: clint@2000000 { + #interrupt-cells = <1>; compatible = "riscv,clint0"; reg = <0x2000000 0xC000>; - interrupts-extended = <&cpu0_intc 3>, <&cpu1_intc 3>; + interrupts-extended = <&cpu0_intc 3 &cpu0_intc 7 + &cpu1_intc 3 &cpu1_intc 7>; clocks = <&sysctl K210_CLK_ACLK>; }; -- 2.25.1