Re: [PATCH] zfcp: fix wrong data and display format of SFP+ temperature

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Benjamin,

> When implementing support for retrieval of local diagnostic data from
> the FCP channel, the wrong data format was assumed for the temperature
> of the local SFP+ connector. The Fibre Channel Link Services (FC-LS-3)
> specification is not clear on the format of the stored integer, and
> only after consulting the SNIA specification SFF-8472 did we realize
> it is stored as two's complement. Thus, the used data and display
> format is wrong, and highly misleading for users when the temperature
> should drop below 0°C (however unlikely that may be).

Applied to 5.6/scsi-fixes, thanks!

-- 
Martin K. Petersen	Oracle Linux Engineering