From: Bartosz Golaszewski <bgolaszewski@xxxxxxxxxxxx> [ Upstream commit cea931c25104e6bddc42eb067f58193f355dbdd7 ] The DM365 platform has a strange quirk (only present when using ancient u-boot - mainline u-boot v2013.01 and later works fine) where if we enable the second half of the timer in periodic mode before we do its initialization - the time won't start flowing and we can't boot. When using more recent u-boot, we can enable the timer, then reinitialize it and all works fine. To work around this issue only enable clockevents once tim34 is initialized i.e. move clockevents_config_and_register() below tim34 initialization. Signed-off-by: Bartosz Golaszewski <bgolaszewski@xxxxxxxxxxxx> Signed-off-by: Sekhar Nori <nsekhar@xxxxxx> Signed-off-by: Sasha Levin <sashal@xxxxxxxxxx> --- drivers/clocksource/timer-davinci.c | 8 ++++---- 1 file changed, 4 insertions(+), 4 deletions(-) diff --git a/drivers/clocksource/timer-davinci.c b/drivers/clocksource/timer-davinci.c index 62745c9620498..e421946a91c5a 100644 --- a/drivers/clocksource/timer-davinci.c +++ b/drivers/clocksource/timer-davinci.c @@ -302,10 +302,6 @@ int __init davinci_timer_register(struct clk *clk, return rv; } - clockevents_config_and_register(&clockevent->dev, tick_rate, - DAVINCI_TIMER_MIN_DELTA, - DAVINCI_TIMER_MAX_DELTA); - davinci_clocksource.dev.rating = 300; davinci_clocksource.dev.read = davinci_clocksource_read; davinci_clocksource.dev.mask = @@ -323,6 +319,10 @@ int __init davinci_timer_register(struct clk *clk, davinci_clocksource_init_tim34(base); } + clockevents_config_and_register(&clockevent->dev, tick_rate, + DAVINCI_TIMER_MIN_DELTA, + DAVINCI_TIMER_MAX_DELTA); + rv = clocksource_register_hz(&davinci_clocksource.dev, tick_rate); if (rv) { pr_err("Unable to register clocksource"); -- 2.20.1