From: Samuel Holland <samuel@xxxxxxxxxxxx> commit dc91c3b6fe66a13ac76f6cb3b2100c0779cd3350 upstream. On AXP288 and newer PMICs, bit 7 of AXP20X_VBUS_IPSOUT_MGMT can be set to prevent using the VBUS input. However, when the VBUS unplugged and plugged back in, the bit automatically resets to zero. We need to set the register as volatile to prevent regmap from caching that bit. Otherwise, regcache will think the bit is already set and not write the register. Fixes: cd53216625a0 ("mfd: axp20x: Fix axp288 volatile ranges") Cc: stable@xxxxxxxxxxxxxxx Signed-off-by: Samuel Holland <samuel@xxxxxxxxxxxx> Reviewed-by: Chen-Yu Tsai <wens@xxxxxxxx> Signed-off-by: Lee Jones <lee.jones@xxxxxxxxxx> Signed-off-by: Greg Kroah-Hartman <gregkh@xxxxxxxxxxxxxxxxxxx> --- drivers/mfd/axp20x.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) --- a/drivers/mfd/axp20x.c +++ b/drivers/mfd/axp20x.c @@ -128,7 +128,7 @@ static const struct regmap_range axp288_ static const struct regmap_range axp288_volatile_ranges[] = { regmap_reg_range(AXP20X_PWR_INPUT_STATUS, AXP288_POWER_REASON), regmap_reg_range(AXP288_BC_GLOBAL, AXP288_BC_GLOBAL), - regmap_reg_range(AXP288_BC_DET_STAT, AXP288_BC_DET_STAT), + regmap_reg_range(AXP288_BC_DET_STAT, AXP20X_VBUS_IPSOUT_MGMT), regmap_reg_range(AXP20X_CHRG_BAK_CTRL, AXP20X_CHRG_BAK_CTRL), regmap_reg_range(AXP20X_IRQ1_EN, AXP20X_IPSOUT_V_HIGH_L), regmap_reg_range(AXP20X_TIMER_CTRL, AXP20X_TIMER_CTRL),