From: Michael Walle <michael@xxxxxxxx> [ Upstream commit 961f8209c8d5ef5d33da42e6656d7c8179899da0 ] The temperature sensor may jump backwards because there is a wrong calibration value. Both values have to be monotonically increasing. Fix it. This was tested on a custom board. Fixes: 571cebfe8e2b ("arm64: dts: ls1028a: Add Thermal Monitor Unit node") Signed-off-by: Michael Walle <michael@xxxxxxxx> Acked-by: Tang Yuantian <andy.tang@xxxxxxx> Signed-off-by: Shawn Guo <shawnguo@xxxxxxxxxx> Signed-off-by: Sasha Levin <sashal@xxxxxxxxxx> --- arch/arm64/boot/dts/freescale/fsl-ls1028a.dtsi | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/arch/arm64/boot/dts/freescale/fsl-ls1028a.dtsi b/arch/arm64/boot/dts/freescale/fsl-ls1028a.dtsi index 72b9a75976a1..c7dae9ec17da 100644 --- a/arch/arm64/boot/dts/freescale/fsl-ls1028a.dtsi +++ b/arch/arm64/boot/dts/freescale/fsl-ls1028a.dtsi @@ -567,7 +567,7 @@ 0x00010004 0x0000003d 0x00010005 0x00000045 0x00010006 0x0000004d - 0x00010007 0x00000045 + 0x00010007 0x00000055 0x00010008 0x0000005e 0x00010009 0x00000066 0x0001000a 0x0000006e -- 2.20.1