Hi, On Mon, Jul 22, 2019 at 10:45:54PM -0400, Paul Cercueil wrote: > The ADC in the JZ4740 can work either in high-precision mode with a 2.5V > range, or in low-precision mode with a 7.5V range. The code in place in > this driver will select the proper scale according to the maximum > voltage of the battery. > > The JZ4770 however only has one mode, with a 6.6V range. If only one > scale is available, there's no need to change it (and nothing to change > it to), and trying to do so will fail with -EINVAL. > > Fixes commit fb24ccfbe1e0 ("power: supply: add Ingenic JZ47xx battery > driver.") There is a standard format for this. It should be Fixes: fb24ccfbe1e0 ("power: supply: add Ingenic JZ47xx battery driver.") > Signed-off-by: Paul Cercueil <paul@xxxxxxxxxxxxxxx> > Cc: stable@xxxxxxxxxxxxxxx Also it would be nice to have an Acked-by from Artur. -- Sebastian > drivers/power/supply/ingenic-battery.c | 4 ++++ > 1 file changed, 4 insertions(+) > > diff --git a/drivers/power/supply/ingenic-battery.c b/drivers/power/supply/ingenic-battery.c > index 35816d4b3012..5a53057b4f64 100644 > --- a/drivers/power/supply/ingenic-battery.c > +++ b/drivers/power/supply/ingenic-battery.c > @@ -80,6 +80,10 @@ static int ingenic_battery_set_scale(struct ingenic_battery *bat) > if (ret != IIO_AVAIL_LIST || scale_type != IIO_VAL_FRACTIONAL_LOG2) > return -EINVAL; > > + /* Only one (fractional) entry - nothing to change */ > + if (scale_len == 2) > + return 0; > + > max_mV = bat->info.voltage_max_design_uv / 1000; > > for (i = 0; i < scale_len; i += 2) { > -- > 2.21.0.593.g511ec345e18 >
Attachment:
signature.asc
Description: PGP signature