Hello, Dmitry Korotin wrote: > Added missing EHB (Execution Hazard Barrier) in mtc0 -> mfc0 sequence. > Without this execution hazard barrier it's possible for the value read > back from the KScratch register to be the value from before the mtc0. > > Reproduciable on P5600 & P6600. > > Mips documentation Volume III (rev 6.03) table 8.1. > > Signed-off-by: Dmitry Korotin <dkorotin@xxxxxxxxxxxx> Applied to mips-fixes. Thanks, Paul [ This message was auto-generated; if you believe anything is incorrect then please email paul.burton@xxxxxxxx to report it. ]