From: Crt Mori <cmo@xxxxxxxxxxx> commit 389fc70b60f534d679aea9a3f05146040ce20d77 upstream. Register EE_VERSION contains mixture of calibration information and DSP version. So far, because calibrations were definite, the driver compatibility depended on whole contents, but in the newer production process the calibration part changes. Because of that, value in EE_VERSION will be changed and to avoid that calibration value is same as DSP version the MSB in calibration part was fixed to 1. That means existing calibrations (medical and consumer) will now have hex values (bits 8 to 15) of 83 and 84 respectively. Driver compatibility should be based only on DSP version part of the EE_VERSION (bits 0 to 7) register. Signed-off-by: Crt Mori <cmo@xxxxxxxxxxx> Cc: <Stable@xxxxxxxxxxxxxxx> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@xxxxxxxxxx> Signed-off-by: Greg Kroah-Hartman <gregkh@xxxxxxxxxxxxxxxxxxx> --- drivers/iio/temperature/mlx90632.c | 9 +++++++-- 1 file changed, 7 insertions(+), 2 deletions(-) --- a/drivers/iio/temperature/mlx90632.c +++ b/drivers/iio/temperature/mlx90632.c @@ -81,6 +81,8 @@ /* Magic constants */ #define MLX90632_ID_MEDICAL 0x0105 /* EEPROM DSPv5 Medical device id */ #define MLX90632_ID_CONSUMER 0x0205 /* EEPROM DSPv5 Consumer device id */ +#define MLX90632_DSP_VERSION 5 /* DSP version */ +#define MLX90632_DSP_MASK GENMASK(7, 0) /* DSP version in EE_VERSION */ #define MLX90632_RESET_CMD 0x0006 /* Reset sensor (address or global) */ #define MLX90632_REF_12 12LL /**< ResCtrlRef value of Ch 1 or Ch 2 */ #define MLX90632_REF_3 12LL /**< ResCtrlRef value of Channel 3 */ @@ -667,10 +669,13 @@ static int mlx90632_probe(struct i2c_cli } else if (read == MLX90632_ID_CONSUMER) { dev_dbg(&client->dev, "Detected Consumer EEPROM calibration %x\n", read); + } else if ((read & MLX90632_DSP_MASK) == MLX90632_DSP_VERSION) { + dev_dbg(&client->dev, + "Detected Unknown EEPROM calibration %x\n", read); } else { dev_err(&client->dev, - "EEPROM version mismatch %x (expected %x or %x)\n", - read, MLX90632_ID_CONSUMER, MLX90632_ID_MEDICAL); + "Wrong DSP version %x (expected %x)\n", + read, MLX90632_DSP_VERSION); return -EPROTONOSUPPORT; }