[ Upstream commit d6423bd03031c020121da26c41a26bd5cc6d0da3 ] There are several Beckhoff Automation industrial PC boards which use pmc_plt_clk* clocks for ethernet controllers. This adds affected boards to critclk_systems DMI table so the clocks are marked as CLK_CRITICAL and not turned off. Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL") Signed-off-by: Steffen Dirkwinkel <s.dirkwinkel@xxxxxxxxxxxx> Signed-off-by: Andy Shevchenko <andriy.shevchenko@xxxxxxxxxxxxxxx> Signed-off-by: Sasha Levin <sashal@xxxxxxxxxx> --- drivers/platform/x86/pmc_atom.c | 24 ++++++++++++++++++++++++ 1 file changed, 24 insertions(+) diff --git a/drivers/platform/x86/pmc_atom.c b/drivers/platform/x86/pmc_atom.c index e3e1f83a2dd7..d4d089c37944 100644 --- a/drivers/platform/x86/pmc_atom.c +++ b/drivers/platform/x86/pmc_atom.c @@ -443,6 +443,30 @@ static const struct dmi_system_id critclk_systems[] = { DMI_MATCH(DMI_PRODUCT_NAME, "3I380D"), }, }, + { + /* pmc_plt_clk* - are used for ethernet controllers */ + .ident = "Beckhoff CB3163", + .matches = { + DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"), + DMI_MATCH(DMI_BOARD_NAME, "CB3163"), + }, + }, + { + /* pmc_plt_clk* - are used for ethernet controllers */ + .ident = "Beckhoff CB6263", + .matches = { + DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"), + DMI_MATCH(DMI_BOARD_NAME, "CB6263"), + }, + }, + { + /* pmc_plt_clk* - are used for ethernet controllers */ + .ident = "Beckhoff CB6363", + .matches = { + DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"), + DMI_MATCH(DMI_BOARD_NAME, "CB6363"), + }, + }, { /*sentinel*/ } }; -- 2.20.1