In this driver the clock is got but never put when the driver is removed or if there is an error in the probe. Using the managed version of clk_get() allows to let the kernel take care of it. Fixes: 1b44c5a60c13 ("crypto: inside-secure - add SafeXcel EIP197 crypto engine driver") cc: stable@xxxxxxxxxxxxxxx Signed-off-by: Gregory CLEMENT <gregory.clement@xxxxxxxxxxx> --- drivers/crypto/inside-secure/safexcel.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/drivers/crypto/inside-secure/safexcel.c b/drivers/crypto/inside-secure/safexcel.c index 384b4ceb37f0..09adeaa0da6b 100644 --- a/drivers/crypto/inside-secure/safexcel.c +++ b/drivers/crypto/inside-secure/safexcel.c @@ -881,7 +881,7 @@ static int safexcel_probe(struct platform_device *pdev) return PTR_ERR(priv->base); } - priv->clk = of_clk_get(dev->of_node, 0); + priv->clk = devm_clk_get(&pdev->dev, NULL); if (!IS_ERR(priv->clk)) { ret = clk_prepare_enable(priv->clk); if (ret) { -- 2.16.1