From: Brian King <brking@xxxxxxxxxxxxxxxxxx> This patch has been added to the 4.1 stable tree. If you have any objections, please let us know. =============== [ Upstream commit 748a240c589824e9121befb1cba5341c319885bc ] This fixes a hang issue seen when changing the MTU size from 1500 MTU to 9000 MTU on both 5717 and 5719 chips. In discussion with Broadcom, they've indicated that these chipsets have the same phy as the 57766 chipset, so the same workarounds apply. This has been tested by IBM on both Power 8 and Power 9 systems as well as by Broadcom on x86 hardware and has been confirmed to resolve the hang issue. Signed-off-by: Brian King <brking@xxxxxxxxxxxxxxxxxx> Signed-off-by: David S. Miller <davem@xxxxxxxxxxxxx> Signed-off-by: Sasha Levin <alexander.levin@xxxxxxxxxxxxx> --- drivers/net/ethernet/broadcom/tg3.c | 4 +++- 1 file changed, 3 insertions(+), 1 deletion(-) diff --git a/drivers/net/ethernet/broadcom/tg3.c b/drivers/net/ethernet/broadcom/tg3.c index f9713fe036ef..7b150085e34d 100644 --- a/drivers/net/ethernet/broadcom/tg3.c +++ b/drivers/net/ethernet/broadcom/tg3.c @@ -14228,7 +14228,9 @@ static int tg3_change_mtu(struct net_device *dev, int new_mtu) /* Reset PHY, otherwise the read DMA engine will be in a mode that * breaks all requests to 256 bytes. */ - if (tg3_asic_rev(tp) == ASIC_REV_57766) + if (tg3_asic_rev(tp) == ASIC_REV_57766 || + tg3_asic_rev(tp) == ASIC_REV_5717 || + tg3_asic_rev(tp) == ASIC_REV_5719) reset_phy = true; err = tg3_restart_hw(tp, reset_phy); -- 2.14.1