This is a note to let you know that I've just added the patch titled hwmon: (pmbus) Use 64bit math for DIRECT format values to the 3.18-stable tree which can be found at: http://www.kernel.org/git/?p=linux/kernel/git/stable/stable-queue.git;a=summary The filename of the patch is: hwmon-pmbus-use-64bit-math-for-direct-format-values.patch and it can be found in the queue-3.18 subdirectory. If you, or anyone else, feels it should not be added to the stable tree, please let <stable@xxxxxxxxxxxxxxx> know about it. >From foo@baz Thu Feb 1 14:48:12 CET 2018 From: Robert Lippert <roblip@xxxxxxxxx> Date: Mon, 27 Nov 2017 15:51:55 -0800 Subject: hwmon: (pmbus) Use 64bit math for DIRECT format values From: Robert Lippert <roblip@xxxxxxxxx> [ Upstream commit bd467e4eababe4c04272c1e646f066db02734c79 ] Power values in the 100s of watt range can easily blow past 32bit math limits when processing everything in microwatts. Use 64bit math instead to avoid these issues on common 32bit ARM BMC platforms. Fixes: 442aba78728e ("hwmon: PMBus device driver") Signed-off-by: Robert Lippert <rlippert@xxxxxxxxxx> Signed-off-by: Guenter Roeck <linux@xxxxxxxxxxxx> Signed-off-by: Sasha Levin <alexander.levin@xxxxxxxxxxxxx> Signed-off-by: Greg Kroah-Hartman <gregkh@xxxxxxxxxxxxxxxxxxx> --- drivers/hwmon/pmbus/pmbus_core.c | 21 ++++++++++++--------- 1 file changed, 12 insertions(+), 9 deletions(-) --- a/drivers/hwmon/pmbus/pmbus_core.c +++ b/drivers/hwmon/pmbus/pmbus_core.c @@ -20,6 +20,7 @@ */ #include <linux/kernel.h> +#include <linux/math64.h> #include <linux/module.h> #include <linux/init.h> #include <linux/err.h> @@ -443,8 +444,8 @@ static long pmbus_reg2data_linear(struct static long pmbus_reg2data_direct(struct pmbus_data *data, struct pmbus_sensor *sensor) { - long val = (s16) sensor->data; - long m, b, R; + s64 b, val = (s16)sensor->data; + s32 m, R; m = data->info->m[sensor->class]; b = data->info->b[sensor->class]; @@ -472,11 +473,12 @@ static long pmbus_reg2data_direct(struct R--; } while (R < 0) { - val = DIV_ROUND_CLOSEST(val, 10); + val = div_s64(val + 5LL, 10L); /* round closest */ R++; } - return (val - b) / m; + val = div_s64(val - b, m); + return clamp_val(val, LONG_MIN, LONG_MAX); } /* @@ -588,7 +590,8 @@ static u16 pmbus_data2reg_linear(struct static u16 pmbus_data2reg_direct(struct pmbus_data *data, struct pmbus_sensor *sensor, long val) { - long m, b, R; + s64 b, val64 = val; + s32 m, R; m = data->info->m[sensor->class]; b = data->info->b[sensor->class]; @@ -605,18 +608,18 @@ static u16 pmbus_data2reg_direct(struct R -= 3; /* Adjust R and b for data in milli-units */ b *= 1000; } - val = val * m + b; + val64 = val64 * m + b; while (R > 0) { - val *= 10; + val64 *= 10; R--; } while (R < 0) { - val = DIV_ROUND_CLOSEST(val, 10); + val64 = div_s64(val64 + 5LL, 10L); /* round closest */ R++; } - return val; + return (u16)clamp_val(val64, S16_MIN, S16_MAX); } static u16 pmbus_data2reg_vid(struct pmbus_data *data, Patches currently in stable-queue which might be from roblip@xxxxxxxxx are queue-3.18/hwmon-pmbus-use-64bit-math-for-direct-format-values.patch