From: Uwe Kleine-König <uwe@xxxxxxxxxxxxxxxxx> commit ac4d4f65bbcba478309de36929016d2618421ba1 upstream. The rtc core calls the .read_alarm with all fields initialized to 0. As the s35390a driver doesn't touch some fields the returned date is interpreted as a date in January 1900. So make sure all fields are set to -1; some of them are then overwritten with the right data depending on the hardware state. In mainline this is done by commit d68778b80dd7 ("rtc: initialize output parameter for read alarm to "uninitialized"") in the core. This is considered to dangerous for stable as it might have side effects for other rtc drivers that might for example rely on alarm->time.tm_sec being initialized to 0. Signed-off-by: Uwe Kleine-König <uwe@xxxxxxxxxxxxxxxxx> Signed-off-by: Willy Tarreau <w@xxxxxx> --- drivers/rtc/rtc-s35390a.c | 14 ++++++++++++++ 1 file changed, 14 insertions(+) diff --git a/drivers/rtc/rtc-s35390a.c b/drivers/rtc/rtc-s35390a.c index f40afdd0..eae8bf2 100644 --- a/drivers/rtc/rtc-s35390a.c +++ b/drivers/rtc/rtc-s35390a.c @@ -265,6 +265,20 @@ static int s35390a_read_alarm(struct i2c_client *client, struct rtc_wkalrm *alm) char buf[3], sts; int i, err; + /* + * initialize all members to -1 to signal the core that they are not + * defined by the hardware. + */ + alm->time.tm_sec = -1; + alm->time.tm_min = -1; + alm->time.tm_hour = -1; + alm->time.tm_mday = -1; + alm->time.tm_mon = -1; + alm->time.tm_year = -1; + alm->time.tm_wday = -1; + alm->time.tm_yday = -1; + alm->time.tm_isdst = -1; + err = s35390a_get_reg(s35390a, S35390A_CMD_STATUS2, &sts, sizeof(sts)); if (err < 0) return err; -- 2.8.0.rc2.1.gbe9624a