On Thursday, March 23, 2017 10:11:12 AM Boris Ostrovsky wrote: > On 03/23/2017 08:52 AM, Juergen Gross wrote: > > Connecting to the backend isn't working reliably in xen-fbfront: in > > case XenbusStateInitWait of the backend has been missed the backend > > transition to XenbusStateConnected will trigger the connected state > > only without doing the actions required when the backend has > > connected. > > > > Cc: stable@xxxxxxxxxxxxxxx > > Signed-off-by: Juergen Gross <jgross@xxxxxxxx> > > Reviewed-by: Boris Ostrovsky <boris.ostrovsky@xxxxxxxxxx> Patch queued for 4.11, thanks. Best regards, -- Bartlomiej Zolnierkiewicz Samsung R&D Institute Poland Samsung Electronics